Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

Health Physics

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Convertors
  • Check Sources
  • Instrument Cases

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

lumic-calibration-v2-v1-m30
lumic-calibration-v2-v1-m30lumic-calibration-v2-m3000-serieslumic-calibration-v1-m3000-series_1953708723lumic-calibration-v1-m30_959150839

Lumic Calibration Kit

Part Number: 4519-865

Features

  • Simplifies Reading and Writing Parameters
  • Wizards for Calibration and Plateau Steps
  • Includes Both Software Versions, 2 Cables, and Manuals

Lumic Calibration Software is a useful tool that allows the reading and writing of important parameters via a USB port in the Model 3000 Series and Model 30 family of instruments. Instrument parameters may be loaded or saved to files, and an instrument parameter report may be printed. The software also allows streaming and viewing of current readings and measurements of the instrument. All streamed readings and measurements are time stamped and may be saved to a CSV file for later viewing.

Two "wizard" features include a gamma exposure/dose calibration routine and an automatic plateau. The calibration routine wizard leads the user through calibration steps. The plateau wizard automatically records data at different detector voltages once the initial settings are input to determine the correct voltage for operation.

The Lumic Calibration Kit includes both versions 1.0 and 2.0 of the Lumic Calibration Software, as well as two USB cables, one for Model 3000 Series instruments and one for the Model 30 family of instruments. See the table below for the firmware requirements and the software version that can be used with each instrument.

Note: If you purchased the original Lumic 1.0 software, you are eligible for a free copy of Lumic 2.0. Please contact your local sales representative or Ludlum Measurements to receive your copy.

 

  • Specifications
  • Documents
  • Specifications
  • Documents

Specifications

Kit Includes:

  • Lumic Calibration Software versions 1.0 and 2.0
  • 2 m (6 ft.) USB-A to USB-A cable Model 3000 Series
  • 2 m (6 ft.) USB-A to USB-Mini-B cable for Model 30 Family
  • Manuals

Software Requirements

  • Windows 7 or higher operating system (32-bit and 64-bit versions)
  • Microsoft .NET Framework 4.5 (installed on most machines by default)
  • Intel or compatible 1 GHz or faster processor (2 GHz or faster is recommended)
  • Minimum of 256 MB of RAM (1 GB or more is recommended)
  • 60 MB of free hard disk space

Instrument Compatibility

Software Version Compatible Models Required Firmware
Lumic 1.0 30, 30-4, 30-6, 30-7, 35, 79 2.x or lower
3000, 3001, 3005, 3006, 3019, 3276 N34 or lower
3002, 3277 N12 or lower
Lumic 2.0 30, 30-4, 30-6, 30-7, 35, 79 3.x or higher
3000, 3001, 3005, 3006, 3019, 3276 N40 or higher
3002 N20 or higher
3003, 3014, 3078 N/A

Note: All new instruments listed in the table above will be compatible with Lumic 2.0. For users with older instruments and who wish to use Lumic 2.0, the latest firmware for each instrument is available for free download on our Software & Firmware downloads page.


Documents

  • Data Sheet
  • Lumic 1.0 Calibration Software Product Manual
  • Lumic 2.0 Calibration Software Product Manual
  • Lumic 1.0 Calibration Software BOM
  • Lumic 2.0 Calibration Software BOM

Related Products

lumic2mainscreen
Lumic Configuration Kit
Results 1 - 1 of 1

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.