Menu
  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Ludlum Measurements Logo
(800) 622-0828 (US, CA)
(325) 235-5494
(325) 235-4672



Field Service Support

To search products by model number, enter "m..."
(Ex: Enter "m3" to search for Model 3.)

  • Home
  • Products
    • All Products
    • Health Physics
    • Medical Physics
    • Metal Recycling
    • Monitoring Systems
    • Emergency Response
    • How To Order
    • Connector Types
  • Support
    • Service Center
    • Training
    • Product Videos
    • Webinars
    • Software & Firmware Downloads
    • Rad Pro Calculator
    • Warranty Plans
    • Radiation Resources
    • Field Service Support
  • Documents
    • Product Manuals
    • Detector Reference Chart
    • Response Curves
    • Test Reports
    • Newsletter Archive
    • Technical Articles
    • End User Statement Form
    • Price List
  • Company
    • About Us
    • Ludlum Family of Companies
    • Directions to Facilities
    • Exhibition Schedule
    • ISO 9001 Certificate
    • ISO/IEC 17025 Accredited
    • Radioactive Material Licenses
    • Mobile App Privacy Policy
    • Sales Tax Business Licences
    • Terms & Conditions
    • Export Information
    • Ethics Policies
  • Careers
  • Contact Us
    • Ludlum Headquarters
    • U.S. Contacts
    • International Contacts
    • Sales Contact Form
    • Feedback Form
Health Physics Medical Physics Metal Recycling Monitoring SystemsEmergency Response

All Products

Portable Survey Meters

  • Friskers
  • General Purpose - Digital
  • General Purpose - Analog
  • Computerized
  • Data Loggers
  • Specialized Meters
  • Geiger Counters
  • Intrinsically Safe
  • Ion Chambers
  • Isotope Identifiers
  • microR / microSv Meters
  • Extended Reach microR / microSv Meters
  • Neutron Meters
  • Pocket-Size Meters
  • Scaler-Ratemeters
  • Stretch Scopes

Personal Radiation Meters

No subcategories

Benchtop Meters

No subcategories

Scalers / Counters

No subcategories

Pulsers

No subcategories

Detectors

  • Alpha
  • Alpha-Beta
  • Alpha-Beta-Gamma
  • Beta
  • Gamma GM
  • Gamma Scintillator
  • Low-Energy Gamma Scintillator
  • Neutron
  • Waterproof Detectors
  • Pipe Detectors
  • Sample Counter Heads
  • Sample Holders

Monitoring Systems

  • Area Monitor Controllers
  • Area Monitoring Systems
  • Portal Monitors
  • Monitoring Systems
  • Contamination Monitors
  • Article Monitors
  • Air Monitors
  • Hand & Foot Monitors
  • Body Monitors
  • Vehicle Monitors
  • Scrap Monitoring Systems
  • Laundry Monitors

Ground/Floor Surveying

No subcategories

Sample Counting

  • Sample Counting Systems
  • Scalers / Counters
  • Sample Counter Heads
  • Protean Instrument Alpha-Beta Counting Systems

Tritium Monitoring

No subcategories

NORM Kits

No subcategories

Dosimetry

  • Dosimeters
  • Dosimeter Accessories

Accessories

  • Detector Accessories
  • Handles & Straps
  • Audio
  • Cables, Connectors & Signal Converters
  • Check Sources
  • Instrument Cases

Medical Physics

  • Radiation Safety QA
  • Imaging QA Test Tools
  • CT / MRI QA
  • Mammography QA
  • Ultrasound QA
  • Nuclear Medicine QA & Safety

Emergency Response Kits

  • General Response Kits
  • Medical Response Kits
  • Decontamination Kits

Need Help?

Unsure about which instrument is best for your application?

Find your region's Ludlum representative or dealer.

  • US Contacts
  • International Contacts

OR

Contact Ludlum Sales:

(800) 622-0828 (USA Toll Free)

(325) 235-5494

Newsletter

Subscribe to our customer newsletter! Stay informed about Ludlum products and services, and get helpful support tips.

Please enable the javascript to submit this form

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

m2241-3i-apr28-09_500px

Model 2241-3i

Digital Scaler-Ratemeter with Internal Detector

Part Number: 48-3358

Features

  • Digital Ratemeter with Built-In Scaler
  • Auto-Ranging
  • Internal GM Detector 10 R/hr
  • Accommodates an External Detector
  • Stores 3 External Detector Setups for Quickly Swapping External Detectors in the Field
  • Adjustable Alarms
  • Overrange & Overload Protection

This instrument is a general purpose, digital ratemeter with a built-in scaler that provides timed counts over a user specified period. This system will store detector setup information for up to four detectors so trained personnel can change detectors in the field. The LCD presents readings in a four-digit moving decimal format together with one of a wide range of available units of measure and is accompanied by several operational and alert icons. The LCD backlight can be activated and remains lit for a user-adjustable interval. This instrument features adjustable alert and alarm setpoints for both the Ratemeter and Scaler modes. Front-panel controls include a rotary switch for selecting between Off, internal GM, and three external detector setups; separate switches for selecting between Ratemeter and Scaler Mode, audio on/off and fast/variable response time; and push-buttons for activating the LCD backlight and for either resetting the counts or acknowledging alarms. Calibration, user configured alarms, scaler count intervals, and detector selection can be configured via an internally housed switchboard or through an RS-232 interface to a PC.

 

  • Specifications
  • Options
  • Documents
  • Software
  • Replacement Parts
  • Specifications
  • Options
  • Documents
  • Software
  • Replacement Parts

Specifications

Indicated Use General purpose survey, gross counting
Internal Detector Energy compensated GM tube
Range: Up to 10 R/hr
Compatible External Detectors GM, Proportional, Scintillation
Detector Setups 4
Display 4-digit LCD display with 1.3 cm (0.5 in.) high digits, separate annunciators for display units, alert, alarm, low battery, detector overload, counting overflow, and scaler counting
Display Range Auto ranging from:
  • 0.0 μR/hr to 9999 R/hr
  • 0.000 μSv/h to 9999 Sv/h
  • 0 cpm to 999 kcpm
  • 0 cps to 100 kcps
Backlight Pushbutton to activate
Ratemeter Can display in R/hr, Sv/h, cpm, or cps when selector switch is in RATE position
Scaler Adjustable from 1 to 9999 s (in 1 s intervals)
Detector Switch Rotating 5-position switch
Alert/Alarm Indicated by annunciation on display and audible tone
High Voltage 400 to 2400 V
Discriminator Adjustable from 2 to 100 mV
Discriminator Adjustments 1
Temperature Range -20 to 50 ºC (-4 to 122 ºF)
RS-232 Port Available in two output formats: binary output or ASCII output. The ASCII output format option requires a firmware change (PN 4408-192).
Power 2 "D" cell batteries housed in an externally accessible, sealed compartment
Battery Life Typically 200 hours with alkaline batteries (low battery warning on LCD)
Size (H x W x L) 16.5 x 8.9 x 21.6 cm (6.5 x 3.5 x 8.5 in.)
Weight 1.6 kg (3.5 lb), including batteries

 The following parameters are adjusted for each detector by a removable switchboard. Once initial setup and calibration have been completed the switchboard can be removed without affecting normal operation of the instrument.

Backlight "ON' Time 5, 15, 30, 60, 90, 120, 180, or 240 seconds for backlight to stay “ON” when activated.
Set Minimum Display Allows lower limit of auto-ranging display to be fixed. For example, display can be set to not show values less than 1 mR/hr.
RS-232 Data Dump Mode Enables or disables binary dump mode to RS-232 port. When enabled binary data will be dumped every 2 seconds.
RS-232 Detector Setup Mode Allows for detector parameters to be input by RS-232 port
Baud Rate 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps
Detector Dead Time Compensation Adjustable from 0 to 9999 µs
Calibration Constant Adjustable from 0.001 to 280 x 109 counts/display unit
Display Units Can display in R/hr, Sv/h, cpm, or cps
Time Base Can display in minutes or seconds
Audio Divide 1, 10, 100, or 1000 events-per-click
Response Time
  • Variable: Dependent on number of counts present. Typical times are FAST 4 to 25 s, SLOW 4 to 60 s (All times stated from 10% to 90% of final reading).
  • Fixed: The parameter is adjustable from 1 to 25 resulting in a FAST response from approximately 2 to 50 s. The SLOW response is approximately 10 to 250 s. For MDA-type measurements, the fixed response mode is recommended.
Ratemeter Alert/Alarm Set at any value within the effective range of each detector
Scaler Alarm Adjustable from 1 to 999999 counts
Scaler Count Time Adjustable from 1 to 9999 s

Options

OptionDescriptionPart Number
m3000-series-shoulder-strap
Shoulder Strap
Adjustable nylon shoulder strap. 4363-413
Headphone Jack
Adds headphone jack to instrument. 4464-464
stereo_mono_headphones
Stereo/Mono Headphones
Adjustable stereo/mono headphones. 22-9313
cs-137_0_25microci
Plastic Disk Check Sources
General purpose check sources used to check instrument response. Depends on source material and activity.
check-source-holder-closed
Mechanical Check Source Holder
Check source holder with swing-away door that attaches to instrument housing. 4062-166
checksourcelabelapplied_500px_419690961
Stick-On Check Source Holder
Adhesive check source holder that attaches to instrument housing. 4464-473

Documents

  • Data Sheet
  • Product Manual
  • Data Logging Data Sheet

Software

Logger and Calibrator Software is available for download on the Software & Firmware Downloads page.


Replacement Parts

DescriptionPart Number
RS-232 Cable (9-pin) 8303-458
RS-232 Cable (25-pin) 8303-459
Meter Bezel 4408-051
Digital Display 5408-259
Rolled Handle 4408-075
Flat Handle 4408-090

Related Products

m3003_web
Model 3003 Series
m3001_face_w_log-button--handle-1b
Model 3001
general_purpose__4c4de8f8b35b6
Model 2241-3
m2241-left-front-angle_no-speaker
Model 2241
m2241-2_bb-trans_500px
Model 2241-2
m2241-2i-rt-angle2-trans_500px
Model 2241-2i
m2241-2i-rt-angle2-trans_500px_667841643
Model 2241-2i/2
Results 1 - 7 of 7

Ludlum Measurements, Inc.
501 Oak Street
Sweetwater, TX 79556
USA

(800) 622-0828 (US & Canada)
(325) 235-5494
(325) 235-4672

All Products

Service Center

Training

About Us

Careers

Ludlum Family

Directions to Facilities

U.S. Contacts

International Contacts

Privacy Policy

Follow Us

LinkedIn

Facebook

YouTube

© 2025 Ludlum Measurements, Inc.